CDBQF - 8400 MAC'S RUBBERIZED UNDERCOAT

Product Identification

Product ID:8400 MAC'S RUBBERIZED UNDERCOAT
MSDS Date:05/31/1989
FSC:9150
NIIN:00F052450
MSDS Number: CDBQF

Responsible Party
VALVOLINE OIL CO (FORMERLY IN ASHLAND KENTUCKY)
3499 DABNEY DR
LEXINGTON, KY 40512-5000
US

Emergency Phone: 606-264-7000/800-274-5263

Info Phone: 606-264-7000/800-274-5263

Cage: 72527

Contractor
VALVOLINE OIL CO
14000 LEXINGTON, KY 40512 US

Telephone: 606-357-7206 / 800-274-5263

Cage: 72527

Ingredients

PROPANE (DIMETHYLMETHANE) *96-4*

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 1-10%

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT


METHANOL (METHYL ALCOHOL), COLUMBIAN SPIRITS *96-4*

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: 1-5%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


STODDARD SOLVENT (PETROLEUM DISTILLATE), MINERAL SPIRITS

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 55-70%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


ISOBUTANE, 2-METHYLPROPANE

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 1-10%

OSHA PEL 1800 MG/CUM

ACGIH TLV: 1000 PPM

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: SEVERE IRRITATION, BLURRED
VISION. SKIN: PROLONGED/REPEATED CONTACT MAY CAUSE MODERATE
IRRITATION, DERMATITIS. INHALATION: MAY CAUSE NASAL & RESPIRATORY
IRRITATION, CNS EFFECTS, ASPHYXIATION. IN GESTION: GASTROINTESTINAL
IRRITATION, ASPIRATION OF MATERIAL INTO THE LUNGS MAY CAUSE
CHEMICAL PNEUMONIA WHICH IS FATAL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, REDNESS, TEARING, BLURRED VISION,
DEFATTING, DIZZINESS, WEAKNESS, FATIGUE, NAUSEA, HEADACHE,
UNCONSCIOUSNESS, ASPHYXIATION, VOMITING, DIARRHEA

First Aid

First Aid:SKIN: THOROUGHLY WASH W/SOAP & WATER. EYES: FLUSH W/LARGE
AMOUNTS OF WATER. INGESTION: DON'T INDUCE VOMITING. KEEP WARM &
QUIET. INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN/CPR IF
NECESSARY. KEEP WAR M & QUIET. OBTAIN MEDICAL ATTENTION IN ALL
CASES.

Fire Fighting

Flash Point:<20F
Lower Limits:1.6
Extinguishing Media:REGULAR FOAM/CO2/DRY CHEMICAL
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS W/A
FULL FACEPIECE OPERATED IN THE POSITIVE PRESSURE DEMAND MODE WHEN
FIGHTING FIRES.
Unusual Fire/Explosion Hazard:VAPORS MAY TRAVEL ALONG THE GROUND/BE
MOVED BY VENTILATION & IGNITED BY IGNITION SOURCES AT LOCATIONS
DISTANT FROM MATERIAL HANDLING POINT.

Accidental Release

Spill Release Procedures:SMALL: ELIMINATE IGNITION SOURCES. ALLOW TO
EVAPORATE. ABSORB ON PAPER/VERMICULITE/FLOOR ABSORBENT/OTHER.
LARGE: ELIMINATE IGNITION SOURCES. ALLOW TO EVAPORATE. KEEP PERSONS
W/O PROTECTED EQUIPMENT AW AY FROM AREA. SOAK UP SPILL
W/VERMICULITE/PERLITE.

Handling

Handling and Storage Precautions:ALL FIVE GALLOW PAILS & LARGER METAL
CONTAINERS, TANK CARS, TANK TRUCKS SHOULD BE GROUNDED/BONDED WHEN
MATERAIL IS TRANSFERRED.
Other Precautions:CONTAINERS MAY BE HAZARDOUS WHEN EMPTIED. SINCE
EMPTIED CONTAINERS RETAIN PRODUCT RESIDUES, VAPOR, LIQUID/SOLID,
PRECAUTIONS MUST BE OBSERVED. NEVER USE WELDING/CUTTING TORCH
ON/NEAR DRUM (EVEN EMPTY) , PRODUCT CAN IGNITE EXPOSIVELY.

Exposure Controls

Respiratory Protection:IF EXPOSURE LIMITS ARE EXCEEDED, USE A
NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR IN ABSENCE OF PROPER
ENVIRONMENTAL CONTROL. NIOSH/MSHA RESPIRATORS (NEGATIVE PRESSURE
TYPE) PERMITTED BY OSHA.
Ventilation:SUFFICIENT MECHANICAL (GENERAL/LOCAL EXHAUST TO MAINTAIN
EXPOSURE BELOW TLV'S.
Protective Gloves:NITRILE RUBBER
Eye Protection:CHEMICAL SPASH GOGGLES/SAFETY GLASSES
Other Protective Equipment:IMPERVIOUS CLOTHING/BOOTS.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:-44.5F
Vapor Pres:9257
Vapor Density:>1
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:LIQUID AEROSOL
Percent Volatiles by Volume:70-85

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:TEMPS >100F, FLARES, FLAMES, PILOT LIGHTS,
ELECTRICAL SPARKS/STATIC DISCHARGE & OTHER IGNITION SOURCES
Hazardous Decomposition Products:CO2, CO, VARIOUS HYDROCARBONS

Disposal

Waste Disposal Methods:SMALL: ALLOW TO EVAPORATE IN HOOD. ALLOW VAPORS
TO COMPLETELY CLEAR HOOD DUCT WORK. LARGE: VENTILATE AREA. ALLOW TO
EVAPORATE. CONTAMINATED ABSORBENT MAY BE DEPOSITED IN A LANDFILL
IAW/LOCAL, STATE & FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.